Colapse All Colapse All

Left Arrow IconPreviousRight Arrow IconNextPlus IconExpandMinus IconCollapseMagnifying Glass IconSearch

theKeyList

KeyOrderSubjectDocumentIdDescriptionLinkFormJSONListNoteIDProcessing GroupSubjectStyleProcessing Sub Group
2Electrical AssemblyEE7DCDC847654E2186257D0300532F60Assembly of the power outlets into the Powerflor<a href="theget/Product-Powerflor+Installation#Electrical+Assembly">Electrical Assembly</a>Content-List Only{documentid:'EE7DCDC847654E2186257D0300532F60',listClass:'',sublist:'no',showTitle:'No',showFooter:'No'}<div class="row list-container">
<div class="col-md-4"><img alt="Installation, Electrical System, Pre-manufactured wiring" src="get/Image-Product-Powerflor Installation/$FILE/Electrical Assembly.jpg" style="height:300px; width:350px" /></div>

<div class="col-md-8">
<div class="grayRight">
<h4><strong><u>Electrical Assembly</u></strong></h4>

<p style="text-align:left">While the floor is being placed, the outlet panels are placed into the floor per the install requirements. Once the floor is placed, duplex outlet inserts are snapped into junction block bases and connected to each other by using our cable assemblies and situated next to its correlating grommet. Then the appropriate floor panels are removed from the system in rows, between the floor and the outlet location. Then electrical outlet chains are placed into the sub floor. The assembled outlet is snapped into the bottom of the grommet, and two locking snap clips are installed. Floor panels are then replaced, covering the electrical system.</p>

<p><u><strong>Powerflor Electrical Install Images:</strong></u></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/outlet placement.jpg" target="_blank">Placing Components</a></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/finishing outlet.jpg" target="_blank">Outlet Mounting</a></p>

<p>Completed installaton</p>
</div>
</div>

<hr />
<p></p>
</div>
0000AB2Electrical Assembly
3Data Assembly49458E4C9F68474B86257D03005346AFPlacing the data panels into the powerflor cable management system<a href="theget/Product-Powerflor+Installation#Data+Assembly">Data Assembly</a>Content-List Only{documentid:'49458E4C9F68474B86257D03005346AF',listClass:'',sublist:'no',showTitle:'No',showFooter:'No'}<div class="row list-container">
<div class="col-md-4"><img alt="Pre-Terminated Cabling, Cat 6, Communication, Data" src="get/Image-Product-Powerflor Installation/$FILE/Data Cable assembly.jpg" style="height:300px; width:350px" /></div>

<div class="col-md-8">
<div class="grayRight">
<h4><strong><u>Data Assembly</u></strong></h4>

<p style="text-align:left">After the electrical assembly is complete the data assembly begins. Pre-terminated communication cable assemblies are rolled out on top of the floor from the network connection point. They are routed in bundled appropriatly for the outlet location. Again appropriate floor panels are removed from the system in rows, between the network connection point and each outlet. Cable bundles are placed in the subfloor and covered with the panels, leaving the jack connectors extending through the grommets. The connections are accatched and secured into the floor and the data install is complete.</p>

<p><u><strong>Powerflor Data Images:</strong></u></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/Routing Cables.jpg" target="_blank">Routing the cables</a></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/outlet placement.jpg" target="_blank">Placing components</a></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/Finishing an Outlet.jpg" target="_blank">Finishing Outlet</a></p>

<p></p>
</div>
</div>

<hr />
<p></p>
</div>
0000972Data Assembly
4Moving the Outlets44AE60E716843C2D86257D030053589AMoving the Poweflor Outlets<a href="theget/Product-Powerflor+Installation#Moving+the+Outlets">Moving the Outlets</a>Content-List Only{documentid:'44AE60E716843C2D86257D030053589A',listClass:'',sublist:'no',showTitle:'No',showFooter:'No'}<div class="row list-container">
<div class="col-md-4"><img alt="Move Panel, Lift Panel, Access Cables" src="get/Image-Product-Powerflor Installation/$FILE/Move Outlets.jpg" style="height:300px; width:350px" /></div>

<div class="col-md-8">
<div class="grayRight">
<h4><strong><u>Moving The Outlets</u></strong></h4>

<p style="text-align:left">Historically moving outlets has been costly and labor intensive, often lacking in location options. With Powerflor that problem is solved. Using a flat bladed tool, remove the selected panel with the coresponding outlet and neccessary adjacent panels. Then simplp reposition the outlet to the desired location and checking all connections. Replace the adjacent panels and your outlet is moved to its new location. With all the panels being the same size, the outlets can be moved to any location within the floor.</p>

<p><u><strong>Moving Outlet Steps:</strong></u></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/Move1med.jpg" target="_blank">Remove Outlet Panel</a></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/Move2-med.jpg" target="_blank">Remove Adjacent Panels</a></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/Move3med.jpg" target="_blank">Relocate Outlet</a></p>

<p><a href="get/Image-Product-Powerflor Installation/$FILE/Move 4med.jpg" target="_blank">Replace Panels</a></p>
</div>
</div>

<hr />
<p></p>
</div>
0000962Moving the Outlets
Show details for Product-Powerflor SpecificationsProduct-Powerflor Specifications
Show details for Product-ProductProduct-Product
Show details for Product-What is PowerflorProduct-What is Powerflor
Show details for Product-What is Powerflor-Specialty OutletsProduct-What is Powerflor-Specialty Outlets
Show details for Product-What is Powerflor-The OutletsProduct-What is Powerflor-The Outlets
Hide details for Product-What is Powerflor-The PanelProduct-What is Powerflor-The Panel
The Powerflor PanelB71E60834C7A621886257D1C006DD086The Powerflor Panel<a href="theget/Product-What+is+Powerflor-The+Panel?opendocument#The+Powerflor+Panel">The Powerflor Panel</a>Content-List Only{documentid:'B71E60834C7A621886257D1C006DD086',listClass:'',sublist:'no'}<div class="row list-container">
<div class="col-md-3"><img alt="" src="get/Image-Product-What is Powerflor/$FILE/panel top .jpg" style="height:250px; width:250px" /></div>

<div class="col-md-6">
<div class="grayCenter">
<h5><strong><u>The Poweflor Panel</u></strong></h5>

<p>Four of the powerflor pedetsals are factory assembled. Four pedestals are attached using a hot glue process that assures proper adhesion. The finished panel will conform to a standard 50cm square carpet tile. Each panel weighs just 8 lbs and is capable of supporting loads up to 50,0000 lbs per square inch. The completed floor panel allows the four pedestals to hinge at both cross points allowing the panel to sit without rocking. This creates a stable platform, and can be provided with any 50cm carpet tile of your choice.</p>

<p><strong><u>Panel Images</u>:</strong></p>

<p><a href="get/Image-Product-What is Powerflor/$FILE/Outlet Panel large.jpg" target="_blank">-Outlet Panel</a></p>

<p><a href="get/Image-Product-What is Powerflor/$FILE/panel top .jpg" target="_blank">-Standard Panel</a></p>
</div>
</div>

<div class="col-md-3" style="padding-left:0px;"><img alt="" src="get/Image-Product-What is Powerflor/$FILE/Pedestal Bottom.jpg" style="height:250px; width:250px" /></div>

<hr />
<p></p>
</div>
0000A3EThe Powerflor Panel
The Powerflor Pedestal5E6252117A9F1A2B86257D1C006DC328The Powerflor Pedestal<a href="theget/Product-What+is+Powerflor-The+Panel?opendocument#The+Powerflor+Pedestal">The Powerflor Pedestal</a>Content-List Only{documentid:'5E6252117A9F1A2B86257D1C006DC328',listClass:'',sublist:'no'}<div class="row list-container">
<div class="col-md-3"><img alt="" src="get/Image-Product-What is Powerflor/$FILE/Top of Pedestal.jpg" style="height:250px; width:250px" /></div>

<div class="col-md-6">
<div class="grayCenter">
<h5><strong><u>The Poweflor Pedestal</u></strong></h5>

<p>The cornerstone of the Powerflor system is a pedestal molded of lightweight, strength re-enforced polycarbonate resin. Designed and Tested to meet the highest industry load bearing standards, this composite material is PVC free and 100% recycleable. This is where the system starts. These pedestals are assembled to create the Powerflor panel.</p>

<p><strong><u>Powerflor Pedestal Manufacturing</u></strong></p>

<p><a href="get/Image-Product-What is Powerflor/$FILE/the mold large.jpg" target="_blank">-The Mold</a></p>

<p><a href="get/Image-Product-What is Powerflor/$FILE/Assembly panel large.jpg" target="_blank">-The Panel</a></p>

<p><a href="get/Image-Product-What is Powerflor/$FILE/Pedestal Large.jpg" target="_blank">-The Assembly</a></p>

<p></p>
</div>
</div>

<div class="col-md-3" style="padding-left:0px;"><img alt="" src="get/Image-Product-What is Powerflor/$FILE/Pedestal Bottom .jpg" style="height:250px; width:250px" /></div>

<hr />
<p></p>
</div>
00009A2The Powerflor Pedestal
Show details for Template-DefaultTemplate-Default
Left Arrow IconPreviousRight Arrow IconNextPlus IconExpandMinus IconCollapseMagnifying Glass IconSearch